HA Blueprints & Design Decisions
Choose your failures before they choose you
Putting the pieces together: reference architectures for 2- and 3-AZ (plus paired region) service tiers, with availability math, blast-radius planning, 'AZ-drain' drills, and the budget vs. nines tradeoff. Design is the practice of picking failures.
What you will learn
- Assemble the 3-AZ reference architecture for a tiered service
- Trace availability math to a budget
- Plan fault-injection drills + blameless design reviews
HA design = decide which single failure the system survives, then assemble redundancy (3-AZ compute, managed DB multi-AZ, queues/cache AZ-redundant) with 'the whole AZ can die' tolerances. Nines only come true after drills prove the wiring.
What is this?
Reference: 3-AZ web+api (ALB), ASG/MIG/azure VMSS across zones, multi-AZ DB, SQS/S3, metrics RGW → dashboards. Regional: paired region for DR (see DR module), Global: route53+CloudFront. Availability budget: nines from parts (0.9999^components ≈), chain vs redundancy; realistically Nines ~= RTO/RPO enforcement not multiplication. Blast radius: batched deploys via lanes, feature flags, config rollout, data-destroying changes quarantined. Drills: AZ sim (stop whole-AZ instances in a test account), DB failover, DNS flip; game-day ≈ chaos engineering matured. Design review checklist (AWS Well-Architected HA pillar / Azure Reliability Hub): MTTR, fault domains, capacity slack vs peak, deviation from nines, and codes. Tradeoffs: double-infra cost, compliance (paired-region demands), ops overhead.
Why do you need it?
- The reference architecture answers 'what does decent look like' — you stop reinventing.
- Availability math turns 'feels OK' into a defendable budget (and tells you where to stop paying).
- Blast-radius design is where 'we're HA' meets 'how did THAT take prod down'.
- Drills turn the blueprint from PowerPoint into muscle memory.
Mental model
A fire escape plan drilled quarterly: third floor → stair A, stairs blocked → stair B
HA drills
The blueprint (escape routes) is useless unless the fire team walks it (drill) enough to know stair B cold under stress. Same for AZ drains: rehearse until the flip is boring.
How it works
- Define the lucky-failure: which single failure must be survived (AZ-loss? instance? DB node?).
- Assemble 3-AZ compute + AZ-redundant data per the blueprint.
- Set the budget: availability target distributes redundancy costs (which parts get 99.99%, which 99.9%).
- Inject: quarterly AZ-drain, DB-failover, config-rollback-dance drills.
- Blast-radius gates (lanes, flags, immutable image) plus review checklist run at design time.
3-AZ reference blueprint.
Examples
Availability budget sanity
# target: service 99.95% (~ 263 min/yr)# budget allocation:# LB/edge ...... .99999# compute fleet .9999# DB ............ .9999 (multi-AZ)# queues ........ .999# crude: product ≈ .9995+... close to 99.95 with slack —# but real practice: count WHAT fails, not percentages alone.A crude chain; reality: MW-failures dominate. Pin the top failure modes per tier and spend the redundancy there.
In production
- Adopt the 3-AZ blueprint for new services; retro-drill legacy via migration plan.
- Quarterly game-day: kill an AZ's compute in a staging mirror, verify dashboards, time to health.
- Well-Architected review on incident days to feed next-quarter HA goals.
Best practices
- State the 'survivable failure' explicitly in an ADR; scope and agree on it.
- Keep AZ-redundant data patterns managed (RDS/Aurora multi-AZ, S3) to reduce custom plumbing.
- Drills are not optional: run failover, flap, and config rollback dance each quarter.
- Size the slack: autoscalers + headroom must cover one-AZ loss within target RTO.
- Treat deploys as HA events: lane-based, gated, revert-ready — never 'hot'.
Common mistakes
- Blueprint only vs. reality: 'we're 3-AZ' but any two pods have the same single instance volume backing them (zone fine, storage not).
- Spending 99.999% effort on compute; the DB single-plane breaks the chain.
- Drills skipped on 'the calendar is hard' → the surprise outage is the drill.
- Cost-anxiety responses that chip away at redundancy until the 'HA' is a fetish.
Debugging tips
- Drill shows failover OK but dashboards blank — dashboards/prom grabbed wrong zone; fix the monitor layer, not the app.
- Capacity melts to 0 during quarter-hour — ASG max insufficient for one-AZ loss scenarios.
- Two failures stacked during drill (AZ + DB flap) — understand chain: DB failover fan-out is your next drill.
- Docs drying up post-drill — enforce drill reports feed the ADR/checklist to encode learnings.
Interview checkpoint
Hands-on lab
- On paper: assemble the tiers (LB/compute/data/queue) for a 92-99% target
- Rehearse the AZ-drain motion against a local mirror
- Write the ADR with survivable-failure + blast radius noted
Design + Drill a 3-AZ Blueprint
45 min · advanced
Quick quiz
In HA design, 'blast radius' means: